Kia Cee'd: Heater / PTC Heater (Diesel Engine) Description and operation

Kia Cee'd JD Service Manual / Heating,Ventilation, Air Conditioning / Heater / PTC Heater (Diesel Engine) Description and operation

Descriptionddd
The PTC (Positive Temperature Coefficient) heater is installed at the exit or the backside of the heater core.
The PTC heater is an electric heater using a PTC element as an auxiliary heating device that supplements deficiency of interior heat source in highly effective diesel engine. The electric heater heats up the interior by directly heating the air that passes through the heater. The name itself implies that the element has a proportional resistance change sensitive to temperature.

Operation Principle
ECM outputs a PTC ON signal and operates PTC relay 1. Then heater controller operates PTC relay 2 and PTC relay 3 with an interval of 15 seconds.
However, PTC relay 3 can be operated while battery voltage is above 12.4V.
Operating Condition
PTC heater operates according to the following conditions :
Battery voltage : 12.4V or above
Engine : Running
Ambient temperature and coolant temperature
 
Ambient
Temperature
Coolant
Temperature
PTC
Operation
Below -20°C
(-4°F)
Below 75°C (167°F)
ON
10°C (50°F)
Below 65°C (149°F)
ON
12°C (53.6°F) or above
-
OFF
-
80°C (176°F) or above
OFF

Mode Control Actuator Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify ...

PTC Heater (Diesel Engine) Repair procedures
Inspection Operating Logic Test (Manual only) Inspect the PTC operation with the confirmation logic below : 1. Entering (1) ...

Other information:

Kia Cee'd JD Owners Manual: ISG system malfunction
The system may not operate when: The ISG related sensors or system error occurs. The following will happen: The yellow AUTO STOP () indicator on the instrument cluster will stay on after blinking for 5 seconds. The light on the ISG OFF button will illuminate. ✽ NOTICE ...

Kia Cee'd JD Service Manual: Condenser Repair procedures
Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2. Check the condenser connections ...

© 2017-2023 www.kceed.com