Kia Cee'd: Blower / Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the blower motor connector (A).

3.
Remove the blower motor (B) after loosening the mounting screws.
4.
Install in the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater & blower assembly. (Refer to Heater - &q ...

Blower Resistor (Manual) Repair procedures
Inspection 1. Measure the resistance between the terminals. 2. If the measured resistance is not within specification, the blower resist ...